Endoscope Bending Section Repair
1. Repair & Replacement: Designed to restore damaged or worn articulation sections of flexible endoscopes.
2. Movement Restoration: Helps recover proper angulation and distal-tip control after component replacement.
3. Structural Renewal: Replacement of worn articulation elements can address deformation, looseness, or restricted movement.
4. Component Matching: Repair parts can be supplied according to the original diameter, segment configuration, and bending range.
5. Refurbishment Support: Suitable for professional endoscope repair centers and refurbishment operations.
Description
Hangzhou Benzgum Medical Technology Co., Ltd. is one of the most reliable manufacturers and suppliers of endoscope bending section repair in China, also supports custom service and OEM&ODM service. With abundant experience, we warmly welcome you to wholesale bulk advanced endoscope bending section repair from our factory.
Repair Solution Overview
Endoscope bending section repair is a core maintenance project for flexible endoscope steering system failure, also known as endoscope articulation repair or bending section reconstruction in the industry. The bending section is subject to long-term repeated bending and disinfection corrosion, which is prone to structural damage and steering failure. We provide complete matching replacement parts for endoscope bending section repair, including standalone bending section bones and pre-assembled bending section assemblies, which can directly replace damaged original parts, accurately restore the steering function of the endoscope, and effectively reduce repair costs compared with original factory repair.
Common Failure & Replacement Guide
- Steering jitter / inaccurate angle: Mostly caused by wear and deformation of bending section joint bones. It is recommended to replace the complete set of bending section parts
- Bending rubber rupture / water ingress: It is necessary to replace the bending rubber and bending mesh at the same time, and check whether the internal bending section bones are corroded
- Insufficient bending angle / unable to steer: Mostly caused by the break of the angulation wire or the falling off of the joint rivet. It can be repaired by replacing the wire or the whole bending section assembly
- Pipeline extrusion deformation: Caused by deformation of the bending section structure. The bending section and the built-in pipeline need to be replaced together
Compatible Repair Model List
We provide pre-assembled bending section assemblies corresponding to mainstream models, which can be used for direct replacement and repair:
|
Assembly No. |
Corresponding Endoscope Model |
Device Category |
|
BSA-2 |
Olympus GIF-H260 |
Gastroscope |
|
BSA-6 |
Olympus CF-H260AI |
Colonoscope |
|
BSA-10 |
Olympus BF-260 |
Bronchoscope |
|
BSA-12 |
Olympus CYF-VA2 |
Cystoscope |
|
BS-29 |
Pentax EG-2990I |
Gastroscope |
|
BS-41 |
Fujifilm EG-590WR |
Gastroscope |
|
BS-42 |
Fujifilm EC-590WI |
Colonoscope |
Note:
The catalogue displayed above covers only a small portion of our product range.
For more available items, please download our complete product list.
Other Products:
- ►Endoscope Insertion Tube
- ►Endoscope Biopsy Channel Tube
- ►Endoscope Air/Water Tube
- ►Endoscope Light Guide Tube
- ►Endoscope Coil Pipe & Assembly
- ►Endoscope Wire & Assembly
- ►Endoscope Bending Section& Assembly
- ►Endoscope Bending Rubber
- ►Endoscope Bending Mesh
- ►Endoscope Stress Boot
- ►Endoscope Repair Tools
- ►Endoscope Light Guide Bundle
- ►Endoscope Valves
Hot Tags: endoscope bending section repair, China endoscope bending section repair manufacturers, suppliers, factory
Send Inquiry
You Might Also Like














