Monopolar Grounding Pad
ESU monopolar grounding pads without cable. Various specifications for Adult, Pediatric and Infant use.
Description
Product Introduction
ESU monopolar grounding pads without cable. Various specifications for Adult, Pediatric and Infant use.
Monopolar grounding pads are typically used in surgeries where electrocautery is required. These pads are placed on the patient's body to complete the electrical circuit and prevent electrical shocks.
The electrosurgical monopolar grounding pad is a medical device used during surgical procedures to prevent electrical current from passing through the patient's body. It is typically made of a flexible, adhesive material with a conductive surface. The pad is placed on the patient's skin and connected to a generator via a cable. The generator sends electrical energy through the surgical instrument to cut or coagulate tissue, but the grounding pad ensures that any stray electrical energy is safely dissipated through the pad and into the generator, preventing harm to the patient. The electrosurgical monopolar grounding pad is an essential component of many surgical procedures, ensuring patient safety and reducing the risk of electrical burns or other complications.


Specification
|
Category |
Product Moel |
Product Description |
Packaging |
|
Electrosurgical patient return electrodes |
LSEP-M1 |
Adult,Monopolar,Vertical |
25 pcs per box, 200 pcs per case |
Product Feature
●Grounding pad monopolar without cable, various sizes for Adults, Pediatric and infant.
●Safe and good adhesive.
●International high quality guaranteed. CE/ISO13485 certificated.
Our Service
●Fast response and confirmation for requests.
●The price is competitive, the quality is guaranteed and the delivery time is reasonable.
●Provide feasible suggestions and benefit maximization solutions to customers.
●The sales team has many years of industry experience and excellent product technical knowledge.
FAQ
●Payment Method : Bank Transfer , Paypal, etc
●Delivery Term: EXW, FOB ,CFR, etc
●Lead Time: 30-45 days
●Transportation : By air , By ocean, UPS/FEDEX/DHL, Aramex, etc
Caution
Please note that the neutral pad should be placed relatively close to the surgical site & must be adhered to the patient before the unit is turned on. Common locations are the upper or lower back, on the stomach or on the patient’s thigh.
How to use the electrosurgical monopolar grounding pad?
1. The electrosurgical monopolar grounding pad is used to provide a safe return path for the electrical current during electrocautery or electrosurgery procedures.
2. The pad should be placed on a clean, dry and hair-free area of the patient's body, preferably on the thigh, buttock or back.
3. The pad should be connected to the electrosurgical generator using a patient lead wire.
4. The generator should be turned on and the power settings should be adjusted as per the requirement of the procedure.
5. Ensure that the grounding pad is securely attached to the patient's skin to avoid any interruptions in the electrical circuit.
6. During the procedure, the surgeon should be cautious not to touch the patient with any metal instrument or part of their body as this can cause an unintended current flow through the patient.
7. After the procedure, the grounding pad should be removed carefully to avoid any damage to the patient's skin.
8. The pad should be disposed of in accordance with the hospital's biohazard waste disposal policies.